Product Zoom Image

CAS 68526-83-0 | Data Package 1 - 10 t/a

Price: POA

Product Features:

Includes:

Study name Short Description Data Owner
Phys-Chem | Appearance / physical state / colour Robust Study Summary -- Title: Average manufacturing data | Author: ExxonMobil Petroleum & Chemical, BVBA | Year: 2008 | Klimisch score: 2 - Reliable with restrictions | Adequacy: key study. -
Phys-Chem | Appearance / physical state / colour Right to refer to study -- Title: Average manufacturing data | Author: ExxonMobil Petroleum & Chemical, BVBA | Year: 2008 | Klimisch score: 2 - Reliable with restrictions | Adequacy: key study. -
Phys-Chem | Melting point / freezing point Robust Study Summary -- Title: Pour point measurement on isooctyl alcohol | Author: ExxonMobil Chemical Company, Brussels, Belgium | Year: 2009 | Klimisch score: 2 - Reliable with restrictions | Adequacy: key study. -
Phys-Chem | Melting point / freezing point Right to refer to study -- Title: Pour point measurement on isooctyl alcohol | Author: ExxonMobil Chemical Company, Brussels, Belgium | Year: 2009 | Klimisch score: 2 - Reliable with restrictions | Adequacy: key study. -
Phys-Chem | Boiling point Robust Study Summary -- Title: Boiling range measurement on isooctyl alcohol | Author: ExxonMobil Chemical Company, Brussels, Belgium | Year: 2009 | Klimisch score: 2 - Reliable with restrictions | Adequacy: key study. -
Phys-Chem | Boiling point Right to refer to study -- Title: Boiling range measurement on isooctyl alcohol | Author: ExxonMobil Chemical Company, Brussels, Belgium | Year: 2009 | Klimisch score: 2 - Reliable with restrictions | Adequacy: key study. -
Phys-Chem | Density Robust Study Summary -- Title: Average manufacturing data | Author: ExxonMobil Petroleum & Chemical | Year: 2008 | Klimisch score: 2 - Reliable with restrictions | Adequacy: key study. -
Phys-Chem | Density Right to refer to study -- Title: Average manufacturing data | Author: ExxonMobil Petroleum & Chemical | Year: 2008 | Klimisch score: 2 - Reliable with restrictions | Adequacy: key study. -
Phys-Chem | Vapour pressure Robust Study Summary -- Title: Vapour pressure calculated by SIMCI PROII V5.5 and ExxonMobil Data Library | Author: ExxonMobil Chemical Company, Brussels, Belgium | Year: 2001 | Klimisch score: 2 - Reliable with restrictions | Adequacy: key study. -
Phys-Chem | Vapour pressure Right to refer to study -- Title: Vapour pressure calculated by SIMCI PROII V5.5 and ExxonMobil Data Library | Author: ExxonMobil Chemical Company, Brussels, Belgium | Year: 2001 | Klimisch score: 2 - Reliable with restrictions | Adequacy: key study. -
Phys-Chem | Vapour pressure Robust Study Summary -- Title: Vapour pressure calculated by EPIWIN | Author: ExxonMobil Biomedical sciences, inc. | Year: 2014 | Klimisch score: 2 - Reliable with restrictions | Adequacy: supporting study. -
Phys-Chem | Vapour pressure Right to refer to study -- Title: Vapour pressure calculated by EPIWIN | Author: ExxonMobil Biomedical sciences, inc. | Year: 2014 | Klimisch score: 2 - Reliable with restrictions | Adequacy: supporting study. -
Phys-Chem | Partition coefficient Robust Study Summary -- Title: N-Octanol/water partition coefficient. Study No. 193387D | Author: ExxonMobil Biomedical Sciences, Inc. | Year: 2001 | Guideline: 117 | Klimisch score: 2 - Reliable with restrictions | Adequacy: key study. -
Phys-Chem | Partition coefficient Right to refer to study -- Title: N-Octanol/water partition coefficient. Study No. 193387D | Author: ExxonMobil Biomedical Sciences, Inc. | Year: 2001 | Guideline: 117 | Klimisch score: 2 - Reliable with restrictions | Adequacy: key study. -
Phys-Chem | Water solubility Robust Study Summary -- Title: EPI SuiteTM (wskOW WIN V1.42). | Author: US EPA - OPPT | Year: 2000 | Klimisch score: 2 - Reliable with restrictions | Adequacy: key study. -
Phys-Chem | Water solubility Robust Study Summary -- Title: Improved method for estimating water solubility from octanol/water partition coefficient | Author: Meylan, W., P. Howard and R. Boethling | Year: 1995 | Klimisch score: 2 - Reliable with restrictions | Adequacy: key study. -
Phys-Chem | Surface tension Robust Study Summary -- Title: surface tension for Isooctyl alcohol | Author: ExxonMobil Chemical Company, Brussels, Belgium | Year: 2009 | Klimisch score: 2 - Reliable with restrictions | Adequacy: key study. -
Phys-Chem | Surface tension Right to refer to study -- Title: surface tension for Isooctyl alcohol | Author: ExxonMobil Chemical Company, Brussels, Belgium | Year: 2009 | Klimisch score: 2 - Reliable with restrictions | Adequacy: key study. -
Phys-Chem | Flash point Robust Study Summary -- Title: Flash point for Isooctyl alcohol | Author: ExxonMobil Chemical Company, Brussels, Belgium | Year: 2009 | Klimisch score: 2 - Reliable with restrictions | Adequacy: key study. -
Phys-Chem | Flash point Right to refer to study -- Title: Flash point for Isooctyl alcohol | Author: ExxonMobil Chemical Company, Brussels, Belgium | Year: 2009 | Klimisch score: 2 - Reliable with restrictions | Adequacy: key study. -
Phys-Chem | Auto flammability Robust Study Summary -- Title: Auto flammability / self-ignition of Isooctyl alcohol | Author: Intertek | Year: 2008 | Klimisch score: 1 - Reliable without restriction | Adequacy: key study. -
Phys-Chem | Auto flammability Right to refer to study -- Title: Auto flammability / self-ignition of Isooctyl alcohol | Author: Intertek | Year: 2008 | Klimisch score: 1 - Reliable without restriction | Adequacy: key study. -
Environmental | Biodegradation in water: screening tests Robust Study Summary -- Title: Ready biodegradability: OECD 301F manometric respirometry test | Author: ExxonMobil | Year: 1997 | Guideline: 301F | Klimisch score: 1 - Reliable without restriction | Adequacy: key study. -
Environmental | Biodegradation in water: screening tests Right to refer to study -- Title: Ready biodegradability: OECD 301F manometric respirometry test | Author: ExxonMobil | Year: 1997 | Guideline: 301F | Klimisch score: 1 - Reliable without restriction | Adequacy: key study. -
Eco-Tox | Short-term toxicity to aquatic invertebrates Robust Study Summary -- Title: The Acute Toxicity of MRD-80-4 to the Water Flea (Daphnia magna Straus) | Author: Union Carbide | Year: 1980 | Klimisch score: 2 - Reliable with restrictions | Adequacy: key study. -
Eco-Tox | Short-term toxicity to aquatic invertebrates Right to refer to study -- Title: The Acute Toxicity of MRD-80-4 to the Water Flea (Daphnia magna Straus) | Author: Union Carbide | Year: 1980 | Klimisch score: 2 - Reliable with restrictions | Adequacy: key study. -
Eco-Tox | Short-term toxicity to aquatic invertebrates Robust Study Summary -- Title: ECOSAR™ Version 1.11. The Ecological Structure Activity Relationship Model Class Program | Author: Mayo-Bean, Kelly | Year: 2012 | Klimisch score: 2 - Reliable with restrictions | Adequacy: supporting study. -
Eco-Tox | Short-term toxicity to aquatic invertebrates Robust Study Summary -- Title: EPI Suite™ Estimation Programs Interface Suite™ for Microsoft® Windows, v 4.11 | Author: US EPA | Year: 2012 | Klimisch score: 2 - Reliable with restrictions | Adequacy: supporting study. -
Eco-Tox | Toxicity to aquatic algae and cyanobacteria Robust Study Summary -- Title: Alga Growth Inhibition Test | Author: EMBSI | Year: 2016 | Guideline: 201 | Klimisch score: 1 - Reliable without restriction | Adequacy: key study. -
Eco-Tox | Toxicity to aquatic algae and cyanobacteria Right to refer to study -- Title: Alga Growth Inhibition Test | Author: EMBSI | Year: 2016 | Guideline: 201 | Klimisch score: 1 - Reliable without restriction | Adequacy: key study. -
Eco-Tox | Toxicity to aquatic algae and cyanobacteria Robust Study Summary -- Title: ECOSAR™ Version 1.11. The Ecological Structure Activity Relationship Model Class Program | Author: Mayo-Bean, Kelly | Year: 2012 | Klimisch score: 2 - Reliable with restrictions | Adequacy: supporting study. -
Eco-Tox | Toxicity to aquatic algae and cyanobacteria Robust Study Summary -- Title: EPI Suite™ Estimation Programs Interface Suite™ for Microsoft® Windows, v 4.11 | Author: US EPA | Year: 2012 | Klimisch score: 2 - Reliable with restrictions | Adequacy: supporting study. -
Toxicological | Acute toxicity: oral Robust Study Summary -- Title: Acute oral toxicity study | Author: ExxonMobil | Year: 1988 | Guideline: 420 | Klimisch score: 1 - Reliable without restriction | Adequacy: key study. -
Toxicological | Acute toxicity: oral Right to refer to study -- Title: Acute oral toxicity study | Author: ExxonMobil | Year: 1988 | Guideline: 420 | Klimisch score: 1 - Reliable without restriction | Adequacy: key study. -
Toxicological | Acute toxicity: oral Robust Study Summary -- Title: Acute oral, acute dermal, and acute inhalation toxicity: isooctyl alcohol | Author: ExxonMobil | Year: 1960 | Guideline: 420 | Klimisch score: 2 - Reliable with restrictions | Adequacy: supporting study. -
Toxicological | Acute toxicity: oral Right to refer to study -- Title: Acute oral, acute dermal, and acute inhalation toxicity: isooctyl alcohol | Author: ExxonMobil | Year: 1960 | Guideline: 420 | Klimisch score: 2 - Reliable with restrictions | Adequacy: supporting study. -
Toxicological | Acute toxicity: oral Robust Study Summary -- Title: Acute toxicity of a homologous series of branched chain primary alcohols | Author: Scala RA and Burtis EG | Year: 1973 | Guideline: 420 | Klimisch score: 2 - Reliable with restrictions | Adequacy: supporting study. -
Toxicological | Skin irritation / corrosion Robust Study Summary -- Title: Primary dermal irritation study in the rabbit | Author: ExxonMobil | Year: 1992 | Guideline: 404 | Klimisch score: 1 - Reliable without restriction | Adequacy: weight of evidence. -
Toxicological | Skin irritation / corrosion Right to refer to study -- Title: Primary dermal irritation study in the rabbit | Author: ExxonMobil | Year: 1992 | Guideline: 404 | Klimisch score: 1 - Reliable without restriction | Adequacy: weight of evidence. -
Toxicological | Skin sensitisation Robust Study Summary -- Title: MultiCASE commercial model A33 for skin sensitization, Danish National Food Institute. | Author: Tine Ringsted, Gunde Egeskov Jensen, Eva Bay Wedebye, Jay Russel Niemelä, Nikolai Nikolov | Year: 2007 | Klimisch score: 2 - Reliable with restrictions | Adequacy: weight of evidence. -
Toxicological | Skin sensitisation Robust Study Summary -- Title: TIMES (TIssue MEtabolism Simulator) model for Skin sensitization (TIMES-SS model) | Author: Chanita Kuseva | Year: 2014 | Klimisch score: 2 - Reliable with restrictions | Adequacy: weight of evidence. -
Toxicological | Skin sensitisation Robust Study Summary -- Title: The sensitization potential of some perfume ingredients tested using a modified Draize procedure | Author: D.W. Sharp | Year: 1978 | Guideline: 406 | Klimisch score: 2 - Reliable with restrictions | Adequacy: key study.
Read-Across (CAS 25339-17-7 | EC 246-869-1 | 3,5 dimethyl octanol-1)
-
Toxicological | Genetic toxicity in vitro Robust Study Summary -- Title: Assessment of Genotoxicity Using the Bacterial Reverse Mutation Test (OECD 471) | Author: Cyprotex, LLC | Year: 2016 | Guideline: 471 | Klimisch score: 1 - Reliable without restriction | Adequacy: key study.
Read-Across (CAS 68526-86-3 | EC 271-235-6 | Branched alcohols, C11-14, C13 rich)
-
Toxicological | Genetic toxicity in vitro Right to refer to study -- Title: Assessment of Genotoxicity Using the Bacterial Reverse Mutation Test (OECD 471) | Author: Cyprotex, LLC | Year: 2016 | Guideline: 471 | Klimisch score: 1 - Reliable without restriction | Adequacy: key study.
Read-Across (CAS 68526-86-3 | EC 271-235-6 | Branched alcohols, C11-14, C13 rich)
-